5.14. 27Error<br />

Error occurrence conditions and check items.<br />

Error<br />

Description<br />

27E<br />

Air volume<br />

sensor error<br />

If an error (open: 0.1±0.1 V or lower / short-circuit: 4.5±0.2 V or higher) in the air<br />

volume sensor is detected continuously for 3 seconds, or if the air volume sensor<br />

voltage of 1.20 V is detected before pre-purge, the system displays the error<br />

message 27E on the room controller and the PCB.<br />

Check items<br />

Check the assembly of the connector of the air volume sensor.<br />

Check the voltage of the air volume sensor.<br />

During fan motor stop, is the<br />

output voltage of APS normal?<br />

No<br />

Replace APS Check Connector<br />

Yes<br />

Check the voltage between black and white wire of<br />

CN 6: 0.2 - 0.6VDC<br />

During fan motor operation,<br />

is the output voltage of APS<br />

normal?<br />

No<br />

Replace APS<br />

Yes<br />

Check the voltage between black and white wire of<br />

CN 6: 1 - 4VDC<br />

Replace PCB<br />

©<strong>Navien</strong> America Inc. 2010<br />

98<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />