5.27.2. Hot water<br />

Error<br />

Cause<br />

Remote controller<br />

power off<br />

Check method<br />

Hot water does not run if the remote controller is switched off.<br />

<strong>Water</strong> heater<br />

fails to work<br />

Defective flow<br />

sensor<br />

The water heater does not work due to the defective flow sensor.<br />

The impeller does not rotate, if the axis is stuck due to foreign<br />

substance.<br />

If the impeller rotates normally, replace the hall sensor of the<br />

flow sensor.<br />

The sensor may be reused temporarily after cleaning, but<br />

replacement must be considered preferentially.<br />

Defective hot<br />

water temperature<br />

sensor<br />

The temperature is sensed higher than the actual temperature due to<br />

a defective hot water (cold water) sensor.<br />

Hot water temperature is low although hot water is recognized by<br />

the remote controller.<br />

The cold temperature sensor may not work without any symptom.<br />

Hot water<br />

setting error<br />

Check the hot water temperature setting on the remote controller.<br />

Low hot water<br />

temperature<br />

<strong>Water</strong> mixed<br />

with cold<br />

water.<br />

The temperature of hot water at the tap is low while the temperature<br />

is high at the hot water outlet.<br />

Cold water and hot water are mixed due to improper pipe<br />

installation.<br />

Cold water and hot water are mixed due to improper installation<br />

of the tap.<br />

No hot water<br />

from the valve<br />

Check the pipe<br />

1. The cold water valve is closed.<br />

2. Check if the cold water filter is clogged with foreign substance.<br />

3. The water adjustment valve is closed. (Refer to E34.)<br />

4. Check if the cold water / hot water pipes are frozen during<br />

the winter.<br />

5. The main heat exchanger is clogged (by lime)<br />

6. Low inlet water pressure<br />

Cold water<br />

flows temporally<br />

Pre-heating<br />

does not work<br />

For the A model, the system performs the internal/<br />

external circulation preheating when 24-hour timer is set on the<br />

remote controller.<br />

Therefore, make sure to check the time setting<br />