#2 Dip Switches<br />
Description<br />
No<br />
Function<br />
ON<br />
OFF<br />
1<br />
Ready-Link<br />
Multi-System Selection<br />
Ready-Link<br />
Multi-System Master<br />
Single Unit Operation or<br />
Multi-System Slave<br />
2<br />
3<br />
4<br />
5<br />
6<br />
7<br />
8<br />
Location select<br />
X<br />
Pump &<br />
Recirculation Selection<br />
Model Select<br />
Korea<br />
X<br />
North America<br />
X<br />
See “ Pump and Recirculation Modes Selection ”<br />
Factory setting<br />
Temperature Select See “ Temperature Selection ”<br />
Pump and Recirculation Modes Selection<br />
Description<br />
With Pump<br />
(NR-180A, NR-210A, NR-240A,<br />
<strong>NP</strong>-180A, <strong>NP</strong>-210A, <strong>NP</strong>-240A)<br />
No Recirculation<br />
External Recirculation<br />
Internal Recirculation<br />
DIP Switch #<br />
4 5<br />
OFF OFF<br />
OFF ON<br />
ON OFF<br />
Without Pump<br />
(NR-180, NR -210, NR -240,<br />
<strong>NP</strong>-180, <strong>NP</strong> -210, <strong>NP</strong> -240)<br />
ON<br />
ON<br />
Temperature Selection<br />
Temperatures<br />
With Pump<br />
(NR-180A, NR-210A, NR-240A,<br />
<strong>NP</strong>-180A, <strong>NP</strong>-210A, <strong>NP</strong>-240A)<br />
Premium<br />
Models<br />
(<strong>NP</strong>,<strong>NP</strong>-A Series)<br />
DIP Switch #<br />
˚F (˚C)<br />
˚F (˚C)<br />
7<br />
8<br />
110 (43)<br />
120 (49)<br />
OFF<br />
OFF<br />
120 (49)<br />
140 (60)<br />
OFF<br />
ON<br />
130 (54)<br />
160 (71)<br />
ON<br />
OFF<br />
140 (60)<br />
185 (85)<br />
ON<br />
ON<br />
©<strong>Navien</strong> America Inc. 2010<br />
35<br />
NR/<strong>NP</strong> series service <strong>Manual</strong><br />
Version 2.0