Off at switch<br />

of stage<br />

Defective air<br />

volume sensor<br />

Foreign sub-stance<br />

in the nozzle<br />

Defective<br />

multistage valve<br />

Flame blowout due to increased blower RPM caused by air pressure<br />

sensor standard value error.<br />

Replace the air pressure sensor.<br />

The flame is extinguished due to foreign substance in the nozzle.<br />

Defective stage-1 nozzle causes accidental fire at ignition.<br />

Flame may be blown out if the stage is switched when the nozzles<br />

of stages 2 and 3 are in trouble.<br />

Disassemble the manifold and clean the nozzle.<br />

(Remove efflo-rescence, if any, from inside wall of the nozzle)<br />

Flame may be blown out if the stage is switched when the multi-stage<br />

valve is defective.<br />

Check the power supply (DC 83~120 V).<br />

Check if the coil is disconnected.<br />

Yellow 2P : State 2 / Red 2P : Stage 3<br />

<br />

Flame blowout<br />

and noise<br />

Other trouble<br />

Defective blower<br />

Defective PCB<br />

A defective proportional valve of the gas block causes trouble in<br />

air supply during combustion.<br />

Low gas pressure causes blowout of flame.<br />

Thick flame causes noise and accidental fire.<br />

If the trouble continues despite the checking of above items, replace<br />

the PCB.<br />

©<strong>Navien</strong> America Inc. 2010<br />

90<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />