4.6.8. Ignition Transformer<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

BH1201041D Check Point O<br />

1. To igniting gas by repeatedly discharging the high voltage spark to the<br />

main burner until igniting gas<br />

1. Unable to ignite during the ignition process.<br />

2. Makes attempts to ignite at all times.<br />

1. The unit cannot ignite during the ignition process and “E003” or “E004”<br />

error codes will display.<br />

2. No effects on the unit, however, the durability of the igniter wears down.<br />

E003, E004<br />

1. Visual inspection: Connection and/or breakage of wires.<br />

2. Voltage check: Check range of voltage shown below.<br />

Blue – Blue : On : AC 97 ~ 138 V<br />

Off : 0 V<br />

<br />

<br />

<br />

Input Voltage<br />

115V, 60Hz<br />

Ouput Voltage<br />

19KV ± 2KV<br />

Ouput Voltage<br />

10mA ± 2mA<br />