4.6.14. <strong>Water</strong> Adjustment Valve<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

AAVC9EXFC003 Check Point N, D<br />

1. To control the water flow for maintain steady hot water temperature.<br />

1. <strong>Water</strong> leakage from the automatic water adjustment valve.<br />

2. The valve cannot modulate or make open/close positions.<br />

1. Stop operating once detecting water leakage.<br />

2. No flames.<br />

3. No operation of the unit.<br />

4. Temperature fluctuations in the hot water outlet.<br />

E034<br />

1. Visual inspection: Connection and/or breakage of wires.<br />

Clean the Domestic cold water inlet filter.<br />

2. Voltage check: Check range of voltage shown below.<br />

Feedback (D) : Red – black : DC 7 ~ 13 V<br />

White – black : Pulse<br />

<strong>Water</strong> Adjust (CW)(N) : Blue – yellow : ON AC 97~138 V, OFF 0 V<br />

<strong>Water</strong> Adjust (CCW)(N) : Blue –orange : ON AC 97~138 V, OFF 0 V<br />

Feedback<br />

Flow adjust<br />

©<strong>Navien</strong> America Inc. 2010<br />

56<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />