5.13. 22Error<br />

Error occurrence conditions and check items.<br />

Error<br />

Description<br />

22E<br />

Heat exchanger<br />

input<br />

temperature<br />

sensor<br />

shortcircuit<br />

If an error (short-circuit: 120 or higher) in the heat exchanger input temperature<br />

sensor is detected, the system displays the 22E error message (cleared automatically)<br />

on the remote controller and the PCB. The boiler maintains the Safety-Shutdown<br />

status.<br />

Check items<br />

1. Check if the heat exchanger input temperature sensor connector is wet due to<br />

any reason, including leakage.<br />

2. Replace the defected heat exchanger input temperature sensor.<br />

3. Replace the PCB.<br />

Is the hot water thermistor 1<br />

normal?<br />

No<br />

Replace hot water thermistor 1<br />

Yes<br />

Resistance between two red wires of CN 13 is from<br />

0.8 to 20k ohm at normal condition.<br />

Check connector<br />

Caution: Before measuring resistance of the thermistor,<br />

remove the connector from the PCB.<br />