5.25. 45Error<br />

Error occurrence conditions and check items<br />

Error<br />

Description<br />

In NR/<strong>NP</strong> type, check the condition of bypass mixing valve when supply power,<br />

turn R/C on/off, or stop burner operation. When bypass mixing valve is noticed<br />

in abnormal condition, display 45E.<br />

45E<br />

Bypass<br />

Mixing<br />

Valve error<br />

Display error code when bypass Mixing valve cannot close.<br />

(Display 16.01 at PCB – generally step motor of bypass mixing valve is in abnormal<br />

condition.)<br />

Display error code when bypass Mixing valve cannot open.<br />

(Display 16.02 at PCB – generally wire of mixing valve is disconnected or feedback<br />

sensor of bypass mixing valve is in abnormal condition.)<br />

Check items<br />

1. Check the connector is connected between bypass mixing valve and PCB.<br />

2. Defective Mixing trans.<br />

3. Defective Bypass Mixing valve<br />

4. Defective PCB.<br />

©<strong>Navien</strong> America Inc. 2010<br />