5.23. 39Error<br />

Error occurrence conditions and check items<br />

Error<br />

39E<br />

Flow sensor<br />

error<br />

Description<br />

As one or more units are operating in the cascade system, if no flow is detected<br />

while the system opens the water adjustment valve, the system considers it as a<br />

defective flow sensor. The system displays 39E (cleared manually) on the remote<br />

controller and the PCB, and switches into the Lock-Out mode (gas valve and ignition<br />

transformer locked).<br />

Check items<br />

1. Check the supply of cold water. (Frozen / locked valve)<br />

2. Defective flow sensor.<br />

3. Defective PCB.<br />

Cancelation cascade<br />

system and faucet open<br />

Yes<br />

<strong>Water</strong> flow out?<br />

No<br />

Check supply cold water<br />

Yes<br />

Check connector<br />

Or Replace water flow sensor<br />