4.6.2. Thermal Fuse<br />

<strong>Navien</strong> Part No.<br />

BH1419012A<br />

BH1419013A<br />

Check Point<br />

N/A<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

1. It protects over limited high temperature in burner due to abnormal operations.<br />

2. The thermal fuse contains solder with a melting point of 383(195).<br />

3. Detects excessive temperature within the unit, especially around the<br />

heat exchanger and combustion chamber. Upon detection, communication<br />

between the PCB and gas valves will sever, shutting down the unit instantly.<br />

1. Unable to detect the excessively high temperature within the unit<br />

1. Flames from burner may penetrate a ruptured/damaged heat exchanger.<br />

2. The water heater is not operating.<br />

N/A<br />

1. Visual inspection: Connection and/or breakage of wires.<br />

2. Voltage check: Check range of voltage shown below.<br />

Black - Black<br />

©<strong>Navien</strong> America Inc. 2010<br />

44<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />