4.6.19. Circulation Pump (“A” Series)<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

PBSNCWBFTANK_001 Check Point P<br />

1. Pump operates for internal or external hot water circulation.<br />

2. Internal circulation will avoid hot and cold water sandwich and external<br />

hot water circulation delivers hot water to fixtures quickly resulting in water<br />

conservation.<br />

3. Applied to the model of NR-A and <strong>NP</strong>-A only.<br />

1. Unable to detect or measure water flow rate. (Only circulation mode)<br />

1. The water heater freezing.<br />

2. Abnormal of internal circulation caused by preheating failure.<br />

3. Abnormal of external circulation caused by preheating failure.<br />

E038<br />

1. Visual inspection: check the circulation pump connection wire.<br />

2. Voltage check: Check range of voltage shown below.<br />

N/A<br />

©<strong>Navien</strong> America Inc. 2010<br />

61<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />