5.19. 35Error<br />

Error occurrence conditions and check items.<br />

Error<br />

35E<br />

<strong>Gas</strong> pres<br />

sure sensor<br />

error<br />

Description<br />

Check the gas pressure sensor. If an error (Open: 0.1±0.1 V or lower / Short-circuit:<br />

4.5±0.2 V or higher) is detected, or if the gas pressure (+) or (-) hose is pulled out,<br />

the system displays 35E (cleared automatically) on the remote controller and the<br />

PCB.<br />

Check items<br />

1. Measure the gas pressure sensor output voltage.<br />

2. Check the connector. (defective contact or short-circuit caused due to moisture)<br />

3. Check the gas pressure hose.<br />

During gas valve ON, is the<br />

output voltage of GPS normal?<br />

No<br />

Replace GPS<br />

Yes<br />

Check the voltage between black and white wire of<br />

CN 7: 0.2 - 0.6VDC<br />

During gas valve OFF, is the<br />

output voltage of GPS normal?<br />

No<br />

Replace GPS<br />

Yes<br />

Check the voltage between black and white wire of<br />

CN 7: 1 - 4VDC<br />

Check connector<br />

©<strong>Navien</strong> America Inc. 2010<br />