5.22. 38Error<br />

Error occurrence conditions and check items.<br />

Error<br />

38E<br />

Pump error<br />

Description<br />

Connect the power, start the pump, and check if the system senses the flow.<br />

If the flow is not sensed after the pump is started, the system displays 38E<br />

(cleared automatically) on the remote controller and the PCB.<br />

Check items<br />

1. Defective flow sensor.<br />

2. Defective pump.<br />

3. Defective PCB.<br />

Is there clod water supply<br />

inside water heater?<br />

No<br />

Supply cold water for water<br />

heater inside<br />

Yes<br />

Circulation PUMP normal<br />

operating?<br />

No<br />

PUMP output voltage<br />

normal?<br />

No<br />

Replace circulation PUMP<br />

Yes<br />

Yes<br />

Check the voltage of CN13:<br />

Over 97V AC<br />

Check water flow sensor<br />

Replace PCB<br />

Or check connector<br />