4.6.13. Burner<br />

PABNCN30KDBN_003<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

PABCR180ABN_002<br />

PABNCW48KDBN_002<br />

PABCR210/240ABN_002<br />

1. Pre-Mixed burner.<br />

2. Pre-Mix system reduces emissions and increase efficiency.<br />

3. The burner facilitates the air/gas mixture necessary to produce the proper<br />

heat during the combustion reaction.<br />

1. Unable to initialize/sustain combustion.<br />

2. Dust or soot deposit on the burner(fin) surface.<br />

3. <strong>Gas</strong> leakage from burners.<br />

1. An unexpected combustion.<br />

2. Unstable flame conditions and/or flame loss.<br />

3. Ignition failure.<br />

E003, E004, E012<br />

Visual inspection: Excessive dust deposit on the burner (fin) surface and<br />

/or unstable flame conditions during operation.<br />

N/A<br />

Check Point<br />

N/A<br />

<br />

<br />

<br />

<br />

<br />

©<strong>Navien</strong> America Inc. 2010<br />

55<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />

Version 2.0