5.8. 10Error<br />

Error occurrence conditions and check items.<br />

Error<br />

10E<br />

Air pressure<br />

error<br />

Description<br />

The system senses the air volume and the RPM signal, and displays 10E on the<br />

indoor thermostat in the following cases:<br />

1. During pre-purge<br />

If the air volume sensor voltage fails to reach the standard voltage (ignition voltage),<br />

while the FAN RPM signal is sensed, the system retries pre-purge. If the air volume<br />

sensor voltage fails to reach the standard voltage after 10 continuous prepurge<br />

actions, the system determines the air pressure error (or the air pressure hose error),<br />

and the boiler switches into Lock-Out.<br />

2. During combustion of boiler<br />

If the current RPM is higher than the standard RPM by 1,000 or higher, the system<br />

determines the air pressure error (excessive air pressure),<br />

and stops the combustion process. The boiler switches into Safety-Shutdown,<br />

and runs the fan continuously. If the current RPM becomes within the standard<br />

RPM ±500, the system cancels the error, and returns to the standby mode.<br />

Check items<br />

1. If the error occurs intermittently, replace the controller with a new model (324-7M).<br />

2. Check the air pressure hose (visual inspection on tear and hole, and water remained<br />

in the hose after installation).<br />

3. Check if the venture (burner) hole is clogged.<br />

4. Check if the condensed water hose or the drain is clogged.<br />

5. Check the flue and exhaust environment. (Inflow of exhaust gas generates noise.)<br />

6. Check if the air supply/exhaust flue is clogged (rainwater collected due to dent or<br />

downward installation).<br />

7. Defective air pressure sensor or PCB.<br />