5.2. 04Error<br />

Error occurrence conditions and check items.<br />

Error<br />

Description<br />

04E<br />

False-flame<br />

detection<br />

1. Pre ignition false-flame<br />

If a flame signal is detected continuously for 6 seconds before combustion<br />

(stand-by, pre-purge, pre-ignition), a false-flame error 04E (automatically cleared)<br />

is dis-played on the thermostat, and the system performs continuous post-purge<br />

and operates the pump.<br />

2. Post purge false-flame<br />

If a flame signal is detected continuously for 6 seconds when the system performs<br />

post-purge as fuel supply is stopped, a false-flame error 04E (automatically cleared)<br />

is displayed on the thermostat, and the system performs continuous post-purge<br />

and operates the pump.<br />

Check items<br />

1. Check if gas leaks due to defective air sealing of the main gas valve.<br />

2. Check if electricity is discharged from the electrode.<br />

3. Check if gas is supplied at higher pressure than the standard gas pressure.<br />

4. Defective PCB.<br />

Is the flame detected<br />

during no burner<br />

openrarion?<br />

No<br />

Clean or replace flame rod<br />

Yes<br />

Check the current of CN 19: 7-20μA<br />

Check the voltage between two wires<br />

of CN 19: 10-20VDC<br />

Replace PCB<br />

©<strong>Navien</strong> America Inc. 2010<br />

75<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />

Version 2.0