5.2. 04Error<br />
Error occurrence conditions and check items.<br />
Error<br />
Description<br />
04E<br />
False-flame<br />
detection<br />
1. Pre ignition false-flame<br />
If a flame signal is detected continuously for 6 seconds before combustion<br />
(stand-by, pre-purge, pre-ignition), a false-flame error 04E (automatically cleared)<br />
is dis-played on the thermostat, and the system performs continuous post-purge<br />
and operates the pump.<br />
2. Post purge false-flame<br />
If a flame signal is detected continuously for 6 seconds when the system performs<br />
post-purge as fuel supply is stopped, a false-flame error 04E (automatically cleared)<br />
is displayed on the thermostat, and the system performs continuous post-purge<br />
and operates the pump.<br />
Check items<br />
1. Check if gas leaks due to defective air sealing of the main gas valve.<br />
2. Check if electricity is discharged from the electrode.<br />
3. Check if gas is supplied at higher pressure than the standard gas pressure.<br />
4. Defective PCB.<br />
Is the flame detected<br />
during no burner<br />
openrarion?<br />
No<br />
Clean or replace flame rod<br />
Yes<br />
Check the current of CN 19: 7-20μA<br />
Check the voltage between two wires<br />
of CN 19: 10-20VDC<br />
Replace PCB<br />
©<strong>Navien</strong> America Inc. 2010<br />
75<br />
NR/<strong>NP</strong> series service <strong>Manual</strong><br />
Version 2.0