- Page 1: Service Manual Service Manual Servi
- Page 5 and 6: 5.12. 21ERROR 95 5.13. 22ERROR 96 5
- Page 7 and 8: Revisions Version Description of ch
- Page 9 and 10: EFFECTIVE DATE The Effective Date o
- Page 11 and 12: Handling of This Manual Scope • T
- Page 13 and 14: 1. Safety Considerations 1.1. Safet
- Page 15 and 16: COMPROMISED VENTING SYSTEM DANGER
- Page 17 and 18: IMPORTANT SAFETY PREAUTIONS DANGER
- Page 19 and 20: 2. Product Information 2.1. Product
- Page 21 and 22: 2.2.2. NP-A Model No Description Na
- Page 23 and 24: 2.2.4. NP Model No Description Navi
- Page 25 and 26: 3.2. Dimensions 3.2.1. NR-A, NP-A M
- Page 27 and 28: 4. System Details 4.1. Schematic an
- Page 29 and 30: 4.1.3. NR Model Exhaust pipe intake
- Page 31 and 32: 4.2. Operation Flow Chart Power ON
- Page 33 and 34: HC minimum range? NO HC minimum ran
- Page 35 and 36: Operation 1. Water Flow Begins •
- Page 37 and 38: #2 Dip Switches Description No Func
- Page 39 and 40: 4.4.2. NP-A Model ©Navien America
- Page 41 and 42: 4.4.4. NP Model ©Navien America In
- Page 43 and 44: Point Function Wire Color Normal Va
- Page 45 and 46: 4.6. Key Components Description 4.6
- Page 47 and 48: 4.6.3. Transformer Navien Part No.
- Page 49 and 50: 4.6.5. Thermistor BH1403081A(Cold)
- Page 51 and 52: 4.6.7. Flame Rod Ass’y Navien Par
- Page 53 and 54:
4.6.9. APS Navien Part No. Function
- Page 55 and 56:
4.6.11. Manifold Navien Part No. Fu
- Page 57 and 58:
4.6.13. Burner PABNCN30KDBN_003 Nav
- Page 59 and 60:
4.6.15. Flow Sensor Navien Part No.
- Page 61 and 62:
4.6.17. Secondary Heat Exchanger Na
- Page 63 and 64:
4.6.19. Circulation Pump (“A” S
- Page 65 and 66:
5. TroubleshootingData 5.1. Error C
- Page 67 and 68:
5.2. 01Error Error occurrence condi
- Page 69 and 70:
5.3. 03Error Error occurrence condi
- Page 71 and 72:
Scenario 3 Is gas valve normally op
- Page 73 and 74:
Electrode gap 3~4mm > < Electrode g
- Page 75 and 76:
PCB DIP S/W capacity setting error
- Page 77 and 78:
5.2. 04Error Error occurrence condi
- Page 79 and 80:
5.2. 07Error Error occurrence condi
- Page 81 and 82:
5.6. 08Error Error occurrence condi
- Page 83 and 84:
5.7. 09Error Error occurrence condi
- Page 85 and 86:
Check method Error type Cause No bl
- Page 87 and 88:
Does APS* have normal operation vol
- Page 89 and 90:
Defective air supply/exhaust flue D
- Page 91 and 92:
Check method Error type Cause Check
- Page 93 and 94:
5.10. 15Error Error occurrence cond
- Page 95 and 96:
Check method Error type Cause Check
- Page 97 and 98:
5.12. 21Error Error occurrence cond
- Page 99 and 100:
Check method Error Defective sensor
- Page 101 and 102:
Check method Error type Cause Conne
- Page 103 and 104:
Check method Error Heat exchanger o
- Page 105 and 106:
5.17. 33Error Error occurrence cond
- Page 107 and 108:
Check method Error Cause Check meth
- Page 109 and 110:
5.19. 35Error Error occurrence cond
- Page 111 and 112:
5.20. 36Error Error occurrence cond
- Page 113 and 114:
Check method Error type No internal
- Page 115 and 116:
Check method Error type Cause Check
- Page 117 and 118:
Check method Error type No hot wate
- Page 119 and 120:
5.24. 44Error Error occurrence cond
- Page 121 and 122:
5.25. 45Error Error occurrence cond
- Page 123 and 124:
Check method Error Defective Bypass
- Page 125 and 126:
Check method Error Cause Check meth
- Page 127 and 128:
Whirring Low gas pressure (whirring
- Page 129 and 130:
5.27.3. Circuit breaker operation E
- Page 131 and 132:
6.2. Measuring Gas Pressure Setting
- Page 133 and 134:
Standard Setting Chart of the Gas-A
- Page 135 and 136:
7.2. Cleaning the Intake Air Filter
- Page 137 and 138:
8. Replacement of Parts 8.1 Replace
- Page 139 and 140:
8.2.2. Fuse Turn off the gas supply
- Page 141 and 142:
8.2.4. Fan Motor(Combustion Air) 1.
- Page 143 and 144:
8.2.6. gnition Transformer 1. Turn
- Page 145 and 146:
8.2.8. Manifold 1. Turn off the gas
- Page 147 and 148:
8.2.9. Main Gas Valve 1. Turn off t
- Page 149 and 150:
8.2.10. GPS 1. Turn off the gas sup
- Page 151 and 152:
8.2.12. Water Adjustment Valve 1. T
- Page 153 and 154:
8.2.14. Buffer Tank (“A” Series
- Page 155 and 156:
13. Replace the O-ring (in service
- Page 157 and 158:
8.2.17. 2-way Valve (“NP-A” “
- Page 159 and 160:
9. Components Diagram and Part List
- Page 161 and 162:
9.2. Burner Disassemble (NR/NP - A,
- Page 163 and 164:
NO Description Navien Part No. Rema
- Page 165 and 166:
9.4. Water Way Disassemble (NR) ©N
- Page 167 and 168:
9.5. Water Way Disassemble (NP) ©N
- Page 169 and 170:
NO Description Navien Part No. Rema
- Page 171 and 172:
10. Inspection and maintenance Sche
- Page 173 and 174:
10.3. Maintenanc Report Inspection
- Page 175 and 176:
Memo ©Navien America Inc. 2010 173
- Page 177 and 178:
Memo ©Navien America Inc. 2010 175