5.17. 33Error<br />
Error occurrence conditions and check items.<br />
Error<br />
33E<br />
Direct water<br />
temperature<br />
sensor<br />
short-circuit<br />
Check items<br />
Description<br />
If an error (open: 248or higher) in the cold water temperature sensor is detected,<br />
the system displays the 33E (cleared automatically) error message on the remote<br />
controller and the PCB. The boiler maintains the Safety-Shutdown status.<br />
1. Check if the hot water temperature sensor connector is wet due to any reason,<br />
including leakage.<br />
2. Replace the defected cold water temperature sensor.<br />
3. Replace the PCB.<br />
Check method<br />
Error<br />
Defective<br />
sensor<br />
Cause<br />
Defective<br />
temperature<br />
sensor connector<br />
Temperature<br />
sensor<br />
Check method<br />
Check if the hot water temperature sensor connector or the PCB<br />
harness terminal is wet due to any reason, including leakage.<br />
Measure the temperature sensor resistance.<br />
Replace the sensor if it is 0 Ω.<br />
Other trouble<br />
Defective<br />
PCB<br />
If the trouble continues despite the checking of above items,<br />
replace the PCB.<br />