5.2. 07Error<br />

Error occurrence conditions and check items.<br />

Error<br />

Description<br />

07E<br />

Hot water<br />

temperature<br />

sensor open<br />

1. Pre ignition false-flame<br />

If a flame signal is detected continuously for 6 seconds before combustion<br />

(stand-by, pre-purge, pre-ignition), a false-flame error 04E (automatically cleared)<br />

is dis-played on the thermostat, and the system performs continuous post-purge<br />

and operates the pump.<br />

2. Post purge false-flame<br />

If a flame signal is detected continuously for 6 seconds when the system performs<br />

post-purge as fuel supply is stopped, a false-flame error 04E (automatically cleared)<br />

is displayed on the thermostat, and the system performs continuous post-purge<br />

and operates the pump.<br />

Check items<br />

1. Check if gas leaks due to defective air sealing of the gas block.<br />

2. Check if electricity is discharged from the electrode.<br />

3. Check if gas is supplied at higher pressure than the standard gas pressure.<br />

4. Defective PCB.<br />

Is the hot water thermistor<br />

normal?<br />

No<br />

Replace hot water thermistor<br />

Yes<br />

Resistance between two red wires of CN 13 is from<br />

0.8 to 20k ohm at normal condition.<br />

Check connector<br />

Caution: B efore measuring resistance of the<br />

thermistor, remove the connector from the PCB<br />

©<strong>Navien</strong> America Inc. 2010<br />

77<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />

Version 2.0