Check method<br />

Error<br />

Defective<br />

sensor<br />

Cause<br />

Defective<br />

temperature sensor<br />

connector<br />

Temperature<br />

sensor<br />

Check method<br />

Check if the temperature sensor connector or the PCB harness<br />

terminal is wet due to any reason, including leakage.<br />

Check the resistance of the temperature sensor.<br />

Replace the temperature sensor if the resistance value is abnormal.<br />

(Defective if it is 0.5 or lower)<br />

Check the temperature displayed on the PCB(C.10.010.0).<br />

Other trouble<br />

Defective<br />

PCB<br />

If the trouble continues despite the checking of above items,<br />

replace the PCB.<br />

< Heat exchanger input temperature sensor /<br />

connector, Black 2P ><br />

< Check if the hot water tem-perature sensor is open ><br />

©<strong>Navien</strong> America Inc. 2010<br />

97<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />