Check method<br />

Error type<br />

Defective<br />

sensor<br />

Cause<br />

Defective contact<br />

of the connector<br />

Defective gas<br />

pressure sensor<br />

Check method<br />

Check the assembly and contact of the gas pressure sensor connector.<br />

Check the gas pressure sensor input/output voltage.<br />

Operating voltage (Black+Blue) : DC 5 V<br />

Sensor output voltage (Black+White)<br />

Open : DC 0.1±0.1 V or lower<br />

Short-circuit: DC 4.5±0.2 V or higher<br />

<br />

<strong>Gas</strong> pressure<br />

hose is pulled<br />

out<br />

Other trouble<br />

<strong>Gas</strong> pressure hose<br />

is pulled out<br />

Defective<br />

PCB<br />

Check the assembly of the gas pressure (+) or (-) hose, and if there is<br />

any damage on the hose.<br />

If the trouble continues despite the checking of above items,<br />

replace the PCB.<br />

©<strong>Navien</strong> America Inc. 2010<br />

108<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />

Version 2.0