Check method<br />

Error type<br />

Sensor error<br />

Other trouble<br />

Cause<br />

Defective<br />

temperature<br />

sensor connector<br />

Temperature<br />

sensor<br />

Defective<br />

PCB<br />

Check method<br />

Check if the hot water temperature sensor connector or the PCB<br />

harness terminal is wet due to any reason, including leakage.<br />

Use a tester to measure the temperature sensor resistance.<br />

If the resistance is abnormal, replace the temperature sensor<br />

(abnormal if it is lower than 0.5).<br />

Check the output temperature displayed on the PCB.<br />

(H.50.550.5)<br />

If the trouble continues despite the checking of above items,<br />

replace the PCB.<br />

<br />

<br />

©<strong>Navien</strong> America Inc. 2010<br />

80<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />

Version 2.0