5.7. 09Error<br />
Error occurrence conditions and check items.<br />
Error<br />
09E<br />
Fan motor<br />
RPM error<br />
Description<br />
The system checks the RPM signal after the blower starts to run, and displays<br />
the error message 09E (cleared manually) in the following cases:<br />
1. If the RPM signal is 400 or lower at pre-purge, the system repeats pre-purge<br />
10 times. If the RPM remains 400 or lower, the system determines RPM error,<br />
and the boiler switches into Lock-Out (gas valve and ignition transformer locked).<br />
(However, the air volume sensor should be normal.)<br />
2. If the RPM signal of 400 or lower is detected for 3 seconds during combustion,<br />
the system stops combustion, and the boiler switches into Lock-Out. (However,<br />
the air volume sensor should be normal.)<br />
3. If the pre-purge RPM signal of 400 or lower is detected, and the voltage of the air<br />
volume sensor is lower than the standard voltage (ignition voltage), the system<br />
de-termines RPM error, and the boiler switches into Lock-Out.<br />
Check items<br />
1. Check if the blower works normally.<br />
2. check the power supply to the blower (Black + Red, approx. DC 127~184 V)<br />
3. If RPM is significantly low while the blower works and the power supply is normal,<br />
replace the blower.<br />
4. If the blower connector is wet due to any reason including leakage, take the<br />
corrective action.<br />
5. Check for loose connection of white tower on PCB<br />