Solenoid<br />

valve<br />

Proportional<br />

valve<br />

Adjusting screw<br />

<br />

Repeated ignition-out<br />

Flame sensing<br />

error<br />

1. Check the location of the flame detecting rod, if there is any<br />

deformation or foreign substance, and repair or replace the part.<br />

2. Check the sheath of the fire detecting wire, and if it is open.<br />

3. Check the grounding to the base, verify grounding at the outlet.<br />

There is a case of defective grounding due to the painting of exterior<br />

base. Therefore, remove the painting in the screw fastening part,<br />

and reconnect.<br />

Or use a tester to measure the flame sensing current.<br />

(normally 3~4 μA)<br />

< Grounding wire<br />

fixing position ><br />

< Measuring flame current ><br />

Defective air<br />

pressure hose<br />

Air pressur<br />

sensor<br />

1. The air pressure hose is broken.<br />

Increased RPM may cause blowout and noise.<br />

2. 10E may occur with the same trouble.<br />

The system works but combustion is not normal due to the defective<br />

air pressure sensor.<br />

Flame blo-wout<br />

and<br />

noise occurs<br />

at ignition<br />

< Defective air pressure hose ><br />

©<strong>Navien</strong> America Inc. 2010<br />