4.6.9. APS<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

NASS9EX00009 Check Point E<br />

1. Sensing the air-pressure for air velocity following gas supply.<br />

2. APS device automatically controls the quantity of air supply operate with GPS.<br />

1. The combustion noise occurs.<br />

2. Imperfect and/or lifting Flame occurs.<br />

1. The water heater is not operating.<br />

2. Excess carbon monoxide emissions.<br />

E009, E010, E027<br />

1. Visual inspection: Connection and/or breakage of wires.<br />

2. Voltage check: Check range of voltage shown below.<br />

1. Red- black : DC 5 V<br />

2. White – black : DC 0.3 ~ 4.5 V<br />