Check method<br />

Error type<br />

Flame before/<br />

after combustion<br />

Cause<br />

Leakage from<br />

main gas valve<br />

Check method<br />

Replace the gas block if flame occurs before combustion or if there is<br />

remaining flame after combustion is stopped.<br />

Discharge of<br />

electricity from<br />

electrode<br />

Spark discharges from electrode to flame sensor at ignition.<br />

Replace or correct location of flame detecting rod.<br />

Error before<br />

after combustion<br />

main gas valve<br />

<strong>Gas</strong> may leak as the main gas valve is pushed by the gas supply over<br />

the standard pressure.<br />

Check the supply pressure: NG: 5”(6” 180 model )~10.5” WC,<br />

LP: 8”(9” 180 model) ~13.5” W.C<br />

If the gas pressure is too high, transfer the problem to the gas<br />

supplier, and replace the main gas valve.<br />

If gas leaks, close the main gas valve and repair the unit before usin<br />

the system.<br />

Other trouble<br />

Defective PCB<br />

If the trouble continues despite the checking of above items,<br />

replace the PCB.<br />