Navien NP Condensing Tankless Gas Water Heater - Service Manual
Navien NP Condensing Tankless Gas Water Heater - Service Manual
Navien NP Condensing Tankless Gas Water Heater - Service Manual
You also want an ePaper? Increase the reach of your titles
YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.
Check method<br />
Error type<br />
Flame before/<br />
after combustion<br />
Cause<br />
Leakage from<br />
main gas valve<br />
Check method<br />
Replace the gas block if flame occurs before combustion or if there is<br />
remaining flame after combustion is stopped.<br />
Discharge of<br />
electricity from<br />
electrode<br />
Spark discharges from electrode to flame sensor at ignition.<br />
Replace or correct location of flame detecting rod.<br />
Error before<br />
after combustion<br />
main gas valve<br />
<strong>Gas</strong> may leak as the main gas valve is pushed by the gas supply over<br />
the standard pressure.<br />
Check the supply pressure: NG: 5”(6” 180 model )~10.5” WC,<br />
LP: 8”(9” 180 model) ~13.5” W.C<br />
If the gas pressure is too high, transfer the problem to the gas<br />
supplier, and replace the main gas valve.<br />
If gas leaks, close the main gas valve and repair the unit before usin<br />
the system.<br />
Other trouble<br />
Defective PCB<br />
If the trouble continues despite the checking of above items,<br />
replace the PCB.<br />
©<strong>Navien</strong> America Inc. 2010<br />
76<br />
NR/<strong>NP</strong> series service <strong>Manual</strong><br />
Version 2.0