5.26. 48Error<br />

Error occurrence conditions and check items<br />

Error<br />

48E<br />

<strong>Gas</strong> pressure<br />

error<br />

Description<br />

For an LP model, if a low-gas pressure is detected at high combustion (Stages 2-2<br />

and 3), the system displays 48E (cleared manually).<br />

If fire breaks out 5 times or more and ignition fails during the combustion after the<br />

low-gas error is detected<br />

If the target APS is out of a specific value range during the combustion with the<br />

gas/air rate adjusted.<br />

Check items<br />

1. Check the gas supply pressure. LP : 8”(9” 180 Model) ~13.5” W.C<br />

(at dynamic pressure)<br />

2. Check if the gas pressure sensor hose is damaged.<br />

3. Check if the gas pressure sensor is defective.<br />

4. Check if the PCB works normally.<br />

LPG <strong>Gas</strong> enough?<br />

No<br />

Fill the LPG <strong>Gas</strong><br />

Yes<br />

Check GPS Or supply Iine<br />

©<strong>Navien</strong> America Inc. 2010<br />