4.6.12. GPS<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

NASS9EXGPS01 Check Point A<br />

1. Sensing the gas-pressure for gas velocity to control combustible air supply.<br />

2. GPS device automatically detects the quantity of gas supply at all times for<br />

ideal combustion with proper air supply.<br />

3. The unit is designed to operate properly even when there’s low gas pressure<br />

supply (within certain range of gas pressure 95 %) because GPS makes<br />

if possible to check and modulate gas ratio for stable combustion.<br />

1. <strong>Gas</strong> leak from the valves.<br />

1. <strong>Gas</strong> leak from the unit.<br />

2. No flames.<br />

3. No operation of the unit.<br />

4. Excess carbon monoxide emissions.<br />

E035, E048(only LP model)<br />

1. Visual inspection: Connection and/or breakage of wires.<br />

2. Voltage check: Check range of voltage shown below.<br />

1. Red- black : DC 5 V<br />

2. White – black : DC 0.3 ~ 4.5 V<br />

©<strong>Navien</strong> America Inc. 2010<br />

54<br />

NR/<strong>NP</strong> series service <strong>Manual</strong><br />

Version 2.0