5.11. 16Error<br />

Error occurrence conditions and check items.<br />

Error<br />

Description<br />

16E<br />

Bimetal<br />

overheated<br />

If the overheat controller on the heat exchanger operates during combustion<br />

stop of the boiler, the system displays the 16E (manually cleared) message on the<br />

remote controller and the PCB. The boiler switches into Lock-Out, and performs<br />

postpurge continuously and operates the pump.<br />

If the overheat sensor signal is detected within 10 min after the combustion is<br />

stopped, no error is displayed, and the system does not start combustion until the<br />

overheat sensor is returned to normal.<br />

Check items<br />

1. Check if the main heat exchanger is clogged.<br />

2. Check if the overheat controller works properly.<br />

3. Check the hot water output/input temperature sensor.<br />

4. Check the PCB DIP S/W capacity setting.<br />

5. Check if the PCB works properly.<br />

Is HTL* normally operation?<br />

No<br />

Replaace HTL<br />

Yes<br />

Replace PCB<br />

Check the resistance betweenteo white wires of CN 13:<br />

short-circuit(016E)<br />

Check the resistance betweenteo white wires of CN 13:<br />

short-circuit(030E)<br />

Caution: Measuning should be done at leat 30 minutes<br />

after error.<br />