5.11. 16Error<br />
Error occurrence conditions and check items.<br />
Error<br />
Description<br />
16E<br />
Bimetal<br />
overheated<br />
If the overheat controller on the heat exchanger operates during combustion<br />
stop of the boiler, the system displays the 16E (manually cleared) message on the<br />
remote controller and the PCB. The boiler switches into Lock-Out, and performs<br />
postpurge continuously and operates the pump.<br />
If the overheat sensor signal is detected within 10 min after the combustion is<br />
stopped, no error is displayed, and the system does not start combustion until the<br />
overheat sensor is returned to normal.<br />
Check items<br />
1. Check if the main heat exchanger is clogged.<br />
2. Check if the overheat controller works properly.<br />
3. Check the hot water output/input temperature sensor.<br />
4. Check the PCB DIP S/W capacity setting.<br />
5. Check if the PCB works properly.<br />
Is HTL* normally operation?<br />
No<br />
Replaace HTL<br />
Yes<br />
Replace PCB<br />
Check the resistance betweenteo white wires of CN 13:<br />
short-circuit(016E)<br />
Check the resistance betweenteo white wires of CN 13:<br />
short-circuit(030E)<br />
Caution: Measuning should be done at leat 30 minutes<br />
after error.<br />
©<strong>Navien</strong> America Inc. 2010<br />
92<br />
NR/<strong>NP</strong> series service <strong>Manual</strong><br />
Version 2.0