4.6.6. Fan motor<br />

<strong>Navien</strong> Part No.<br />

Function<br />

Failure Event<br />

Effects<br />

Error Code<br />

Diagnostic<br />

Color /<br />

Number of wires<br />

NAFA9GSFB002 Check Point L<br />

To provide combustion air into the burner and to exhaust flue gas.<br />

Fan operated with APS or ideal combustion.<br />

1. Fan speed failure: the fan RPM are less than or equal to 400 RPM.<br />

2. The fan assembly screw loosens and/or the fan is disassembled.<br />

3. Connection terminal assembly defectiveness.<br />

1. Unstable combustion condition.<br />

2. Unit vibrating and making a noise.<br />

3. The water heater is not operating.<br />

E009, E010, E027<br />

1. Visual inspection: check the fan connection wire and/or the fan mounting<br />

location.<br />

2. Voltage check: Check range of voltage shown below.<br />

1. Black-Red : DC 127 ~ 184 V<br />

2. Black-Yellow : DC 15 V<br />

3. Black-Orange : DC 0~7.5 V<br />

4. Black-White : 0 ~ 6,500 RPM<br />