<strong>CETAC</strong> QuickTrace M-<strong>7600</strong> <strong>Mercury</strong> <strong>Analyzer</strong><br />

Chapter 1: Introduction<br />

System Features<br />

The QuickTrace M-<strong>7600</strong> incorporates the following features to form an<br />

automated, integrated mercury analysis system.<br />

‣ Computer-controlled four-channel high-performance peristaltic pump<br />

(12-roller pump head).<br />

‣ Ozone-free Hg Lamp. No lamp ventilation is needed.<br />

‣ Thermally controlled Hg lamp housing (for a stabilized Hg vapor lamp).<br />

‣ Stable high performance Gas-Liquid Separator (GLS). (U.S. Patent<br />

#5,792,663). Non-foaming/non-bubbling “thin liquid film” GLS design,<br />

which allows trouble-free direct analysis of blood, urine, and fish tissue<br />

digests as well as standard water and waste analysis.<br />

‣ Rigid, shock and vibration-isolated optical rail (mounting the Hg lamp,<br />

collimator lens, absorption tubes, camera, CCD detector, and A/D<br />

converter).<br />

‣ Precise, self-aligning optical mounts, no optical alignment required,<br />

maximizing the convenience of instrument baseline zeroing. This design<br />

extends maintenance intervals without loss of performance.<br />

‣ Long path (220 mm) absorbance cells.<br />

‣ Hg lamp electro-optical feedback beam utilizing a high-performance solidstate<br />

detector for ultra-fine lamp stabilization.<br />

‣ Fixed optical interference filters, three each (254 ± 2 nm wavelength, 20%<br />

T, 12.7 mm dia.). No moving parts.<br />

‣ Standard Perma Pure ® dryer cartridge eliminates the need for Mg(ClO 4) 2<br />

drying agent.<br />

‣ Stabilized double beam optics - traditional double-beam (sample and<br />

reference) with a CCD detector.<br />

‣ Internal ADC (Analog-to-Digital Conversion).<br />

‣ High-rate data sampling.<br />

‣ Computer controlled system shutdown/standby routines.<br />

‣ Integrated optional autosamplers for accommodation of calibration<br />

standards and up to 720 samples.<br />

‣ Ethernet communications.<br />

‣ Gas exhaust Hg vapor safety trap (solid crystalline KMnO 4).<br />

9