T.P.D.M.V.2.3<br />

(Al/2001)<br />

Table 3.7.7.2<br />

Design Standards for Footbridges and Subways<br />

Minimum :#<br />

effective<br />

width<br />

Minimum :#<br />

vertical<br />

clearance<br />

Ramps :<br />

Footbridges<br />

2m (except on stairs to Tram or similar<br />

platforms where a lesser width is necessary<br />

because of limited space)<br />

5.1m<br />

Subways<br />

3tn<br />

2.3m (for length less than 23m)<br />

2.5m (for length not less than 23m)<br />

Where possible both ramps and stairs should be provided on all approaches.<br />

Desirable maximum gradient = 1 in 12<br />

Stairwavs :<br />

Landings :*<br />

Handrails<br />

_•<br />

Absolute maximum gradient = 1 in 10<br />

Centre line of circular ramps should never exceed 10%<br />

Stepped ramps should not be provided<br />

Desirable maximum height of risers = 150mm ) Values chosen for<br />

Absolute maximum height of risers = 165mm ) riser height 'R' and<br />

(in exceptional circumstances only) ) tread width T<br />

Desirable minimum width of tread = 280mm ) must satisfy both:<br />

Absolute minimum width of tread<br />

Desirable maximum flight of steps<br />

Absolute maximum flight of steps<br />

= 250mm ) 2R+T = 580 to 600 T x<br />

R = 42000 to 45000<br />

= 1 2 risers<br />

= 1 6 risers<br />

Ramps steeper than 10% to have landings at vertical intervals not greater than<br />

3500mm.<br />

Ramps of 10% or less to have landings at vertical intervals not greater than<br />

3500mm where space permits.<br />

Desirable length for stairs<br />

Absolute minimum length for stairs<br />

Desirable length for ramps<br />

Absolute minimum length for ramps<br />

Width of all landings<br />

= 1500mm - 1800mm<br />

= 1 000mm<br />

= 2000mm<br />

= 1 500mm<br />

= Not less than that of the approach<br />

stairs or ramps<br />

Handrails must be provided on both sides of all ramps and stairways, and<br />

consideration should be given to the provision of central handrails on stairways<br />

4000mm wide or more.<br />

* Ramps with gradients above 10% require approval from the respective AC for T/Region.<br />

# Adequate allowance should be made for railings/handrails, lightings, finishes, etc in<br />