Fig. 41<br />
3. Install breather deflector (2) and two screws (3).<br />
Do not tighten at this time.<br />
4. Install two air cleaner support screws (4). Torque<br />
screws to 65 in. lbs. (7 Nm).<br />
Make sure air inlet tube is installed correctly in air<br />
cleaner base.<br />
Models 351400, 380400<br />
1. Install new air cleaner mounting gasket (2) with<br />
adhesive side toward air cleaner base, Fig. 42.<br />
2. Connect breather tube to air cleaner base and<br />
assemble air cleaner base to air cleaner elbow.<br />
3. Install carburetor shield (1). Install five screws<br />
finger tight. Torque screws to 65 in. lbs. (7 Nm).<br />
Make sure air inlet tube is installed correctly in air<br />
cleaner base.<br />
<br />
Fig. 43<br />
2. With the outlet tube (7) to the LEFT, service cover<br />
(3) to the RIGHT, install the mounting band (4).<br />
NOTE: The air cleaner is held in place by the<br />
mounting band. The mounting band has a<br />
TENSIONER ADJUSTING SLOT (5) that<br />
runs vertically and faces the front of the<br />
engine, the SIDE ADJUSTER SLOT (6)<br />
runs horizontally and faces the back.<br />
3. Align the tabs on the inside of the mounting band<br />
with the slots on the outside of the air cleaner<br />
housing. Fasten the SIDE ADJUSTER SLOT<br />
first.<br />
Fig. 42<br />
<br />
4. Push the mounting band closed and fasten the<br />
TENSIONER ADJUSTING SLOT. Tighten both<br />
mounting band screws to 200 in. lbs. (23 Nm).<br />
5. Connect the air inlet hose (1) to the outlet<br />
tube (7). Tighten both hose clamps to 30 in. lbs.<br />
(3.4 Nm).<br />
Models 540000, 610000<br />
1. Orient the air cleaner with the air inlet (2) facing<br />
UP. Tighten the air inlet hose clamp to 30 in. lbs.<br />
(3.4 Nm), Fig. 43.<br />
NOTE: The end of the air inlet hose with the white<br />
stripe connects to the outlet tube of the air<br />
cleaner. The white stripe (8) on the air inlet<br />
hose faces UP as shown.<br />