Fig. 41<br />

3. Install breather deflector (2) and two screws (3).<br />

Do not tighten at this time.<br />

4. Install two air cleaner support screws (4). Torque<br />

screws to 65 in. lbs. (7 Nm).<br />

Make sure air inlet tube is installed correctly in air<br />

cleaner base.<br />

Models 351400, 380400<br />

1. Install new air cleaner mounting gasket (2) with<br />

adhesive side toward air cleaner base, Fig. 42.<br />

2. Connect breather tube to air cleaner base and<br />

assemble air cleaner base to air cleaner elbow.<br />

3. Install carburetor shield (1). Install five screws<br />

finger tight. Torque screws to 65 in. lbs. (7 Nm).<br />

Make sure air inlet tube is installed correctly in air<br />

cleaner base.<br />

<br />

Fig. 43<br />

2. With the outlet tube (7) to the LEFT, service cover<br />

(3) to the RIGHT, install the mounting band (4).<br />

NOTE: The air cleaner is held in place by the<br />

mounting band. The mounting band has a<br />

TENSIONER ADJUSTING SLOT (5) that<br />

runs vertically and faces the front of the<br />

engine, the SIDE ADJUSTER SLOT (6)<br />

runs horizontally and faces the back.<br />

3. Align the tabs on the inside of the mounting band<br />

with the slots on the outside of the air cleaner<br />

housing. Fasten the SIDE ADJUSTER SLOT<br />

first.<br />

Fig. 42<br />

<br />

4. Push the mounting band closed and fasten the<br />

TENSIONER ADJUSTING SLOT. Tighten both<br />

mounting band screws to 200 in. lbs. (23 Nm).<br />

5. Connect the air inlet hose (1) to the outlet<br />

tube (7). Tighten both hose clamps to 30 in. lbs.<br />

(3.4 Nm).<br />

Models 540000, 610000<br />

1. Orient the air cleaner with the air inlet (2) facing<br />

UP. Tighten the air inlet hose clamp to 30 in. lbs.<br />

(3.4 Nm), Fig. 43.<br />

NOTE: The end of the air inlet hose with the white<br />

stripe connects to the outlet tube of the air<br />

cleaner. The white stripe (8) on the air inlet<br />

hose faces UP as shown.<br />