Two types of pulse command can be connected, (Open collector) and (Line driver).<br />

Please refer to section 2-2-1 for the pulse wiring method.<br />

Pulse command timing should be in accordance with the time sequence standard below.<br />

Pulse Command<br />

Types<br />

Time Sequence Diagram of Pulse Command<br />

Time Standard<br />

Line Driver:<br />

t1, t2 ≦ 0.1μs<br />

(Pulse)+ Pulse<br />

t3 > 3μs<br />

T<br />

t3 t3<br />

t1<br />

τ ≧ 1.0μs<br />

(τ/T) ≦ 50%<br />

(Sign)<br />

t2 t<br />

t2<br />

OpenCollector:<br />

Sign<br />

t1, t2 ≦ 0.2μs<br />

t3 > 3μs<br />

τ ≧ 2.0μs<br />

(τ/T) ≦ 50%<br />

LineDrive:<br />

t1, t2 ≦ 0.1μs<br />

t1<br />

T<br />

t3 > 3μs<br />

τ ≧ 1.0μs<br />

Pulse<br />

(CCW)/<br />

(τ/T) ≦ 50%<br />

(CW) Pulse<br />

t2 t<br />

OpenCollector:<br />

Sign<br />

t1, t2 ≦ 0.2μs<br />

t3<br />

t3 > 3μs<br />

τ ≧ 2.0μs<br />

(τ/T) ≦ 50%<br />

LineDrive:<br />

t1<br />

t1, t2 ≦ 0.1μs<br />

τ ≧ 1.0μs<br />

Pulse<br />

(τ/T) ≦ 50%<br />

AB-Phase Pulse<br />

Sign<br />

t2<br />

T<br />

t<br />

OpenCollector:<br />

t1, t2 ≦ 0.2μs<br />

τ ≧ 2.0μs<br />

(τ/T) ≦ 50%<br />

Position command can be disabled ( Inhibited) by extrernal input contact INH.<br />

Input Contact<br />

INH<br />

Description<br />

Control<br />

Mode<br />

0 Position Pulse command enabled<br />

1 Position Pulse command disabled<br />

Pe<br />

Note: Input contacts status “1” (ON) and “0” (OFF)<br />

Please check section 5-6-1 to set the required high /Low signal levels ( PNP/NPN) selection.<br />