Digital Outputs.<br />

There are 4 programmable Digital Outputs according to the table below:<br />

Parameter Name Setting Description<br />

★Hn514.0<br />

★Hn514.1<br />

★Hn514.2<br />

DO-1 Logic<br />

state<br />

DO-1<br />

Code<br />

01 RDY Servo Ready<br />

02 ALM Alarm<br />

03 ZS Zero Speed<br />

04 BI Brake Signal<br />

05 INS In Speed<br />

06 INP In Position<br />

07 HOME HOME<br />

08 INT In Torque<br />

Contactor functions<br />

0 Close, when the output is activated.<br />

1 Open, when the output is activated..<br />

Control<br />

Mode<br />

ALL<br />

ALL<br />

Parameter Name Description<br />

★Hn515<br />

★Hn516<br />

★Hn517<br />

DO-2 Programmable<br />

DO-3 Programmable<br />

DO-4 Programmable<br />

Refer to Hn514 for programmable options.<br />

Control<br />

Mode<br />

New setting will become effective after re-cycling the power.<br />

Warning!<br />

When programmable DO-1 ~ DO-4 are set for the same type of function alarm will be displayed.<br />

AL-07 (Multi-function contact setting error).<br />