5-2-7 Additional torque control functions<br />

Torque Output Monitor<br />

When the torque level in CW or CCW directions becomes greater than the value set in<br />

Tn108 (torque level monitor value), the output contact INT is active.<br />

Parameter Name Default Unit Setting range Control mode<br />

Tn108<br />

Torque output monitor<br />

level<br />

100 % 0~300 ALL<br />

Note: Input contacts status “1” (ON) and “0” (OFF).<br />

Please check 5-6-1 to set the required high /Low signal levels (PNP/NPN) selection.<br />

Torque Smoothing Filter<br />

Torque vibration can be diminution by setting an appropriate value in Cn034 (Torque command smoothing<br />

filter), In the other hand, this will cause a delay in the response time of the torque loop.<br />

Parameter Name Default Unit Setting range Control mode<br />

Cn034<br />

Torque smoothing<br />

filter<br />

0 Hz 0~1000 ALL<br />

5-8