dn-02 (Output terminal status)<br />

Use dn-02 to check the status of output terminals.<br />

Output status display is described below:<br />

When output terminal signal has a low logic level (close loop with IG24),<br />

the corresponding LED will be on.<br />

When output terminal signal has a high logic level (open loop with IG24),<br />

the corresponding LED will be off.<br />

Table below shows the functions of the digital outputs.<br />

DO-1~DO-4 are programmable outputs. Default settings are shown below.<br />

DO-5~DO-8 are fix function outputs. ( non-programmable)<br />

For programmable output list see section 5-6-1.<br />

LED No. Output terminal number Default function<br />

1 DO-1 RDY<br />

2 DO-2 ALM<br />

3 DO-3 ZS<br />

4 DO-4 INP<br />

5 DO-5 LM/A0<br />

6 DO-6 PC/A1<br />

7 DO-7 ST/A2<br />

8 DO-8 BB/A3<br />

Note: To set the logic state (High or Low) of for programmable digital outputs refer<br />

to section 5-6-1.<br />

For the DO-5~DO-8 ( non-programmable) terminals are active when logic is low.<br />

3-8