Speed-Control Parameter<br />
Parameter Name & Function Default Unit<br />
Sn201<br />
Sn202<br />
Sn203<br />
Sn204<br />
Sn205<br />
Internal Speed Command 1<br />
In Speed control, input contacts SPD1 and SPD2 can<br />
be used to select 3 sets of internal speed command,<br />
select for speed command 1 contact status shows<br />
below:<br />
Input Contact SPD2 Input Contact SPD1<br />
0 1<br />
Note: Input contacts status “1” (ON) and “0” (OFF)<br />
Refer to 5-6-1 to set high or low input logic levels.<br />
Internal Speed Command 2<br />
In Speed control, input contacts SPD1 and SPD2 can<br />
be used to select 3 sets of internal speed command,<br />
select for speed command 2 contact status shows<br />
below:<br />
Input Contact SPD2 Input Contact SPD1<br />
1 0<br />
Note: Input contacts status “1” (ON) and “0” (OFF)<br />
Refer to 5-6-1 to set high or low input logic levels.<br />
Internal Speed Command 3<br />
In Speed control, input contacts SPD1 and SPD2 can<br />
be used to select 3 sets of internal speed command,<br />
select for speed command 3 contact status shows<br />
below:<br />
Input Contact SPD2 Input Contact SPD1<br />
1 1<br />
Note: Input contacts status “1” (ON) and “0” (OFF).<br />
Refer to 5-6-1 to set high or low input logic levels.<br />
Zero Speed selection Enable or Disable the zero<br />
speed preset parameter Sn215.<br />
Setting<br />
Explanation<br />
No Action. ( Sn215 zero preset is not<br />
0<br />
effective).<br />
1 Set the preset value in Sn215 as zero speed.<br />
Speed command accel/decel smooth method.<br />
Setting<br />
Explanation<br />
0 By Step response<br />
Smooth Acceleration/deceleration according<br />
1<br />
to the curve defined by Sn206.<br />
Linear accel/decel time constant .Defined by<br />
2<br />
Sn207<br />
S curve for Acceleration/deceleration. Defined<br />
3<br />
by Sn208.<br />
100 rpm<br />
200 rpm<br />
300 rpm<br />
0 X<br />
0 X<br />
Setting<br />
Range<br />
-3000<br />
│<br />
3000<br />
-3000<br />
│<br />
3000<br />
-3000<br />
│<br />
3000<br />
0<br />
│<br />
1<br />
0<br />
│<br />
3<br />
Control<br />
Mode<br />
Chapter<br />
S 5-3-1<br />
S 5-3-1<br />
S 5-3-1<br />
S 5-3-12<br />
S 5-3-6<br />