DRAFT RECOMMENDED STANDARD FOR SPACE LINK EXTENSION SERVICE MANAGEMENT<br />

Name Definition/Description Data Type Units<br />

pcmFormatOptions<br />

Set of PCM formats that may be modulated onto the<br />

carrier or subcarrier during the lifetime of the <strong>Service</strong><br />

Agreement. It contains any combination of the<br />

following values, with no repeated components:<br />

– ‘NRZ-L’—no return to zero-level;<br />

– ‘NRZ-M’—no return to zero-mark;<br />

– ‘SP-L’—split phase level.<br />

The set shall contain at least one component.<br />

set of Enums n/a<br />

fSubcarrierFrequency-<br />

Range<br />

Table 7-29: F401SubcarrierAgreement Data Set<br />

Name Definition/Description Data Type Units<br />

The minimum and maximum values for the forward pair of Hz<br />

subcarrier frequency allowed during the lifetime of Unsigned<br />

the <strong>Service</strong> Agreement.<br />

Integers<br />

subcarrierWaveform-<br />

Options<br />

The subcarrier waveforms that will be used during<br />

the lifetime of the <strong>Service</strong> Agreement. It contains any<br />

combination of the following values, with no<br />

repeated components:<br />

– ‘sine’—sine wave;<br />

– ‘square’—square wave.<br />

The set shall contain at least one component.<br />

set of Enums<br />

n/a<br />

Table 7-30: F401SymbolStreamAgreement Data Set<br />

Name Definition/Description Data Type Units<br />

symbolRateRange<br />

The minimum and maximum values for the symbol<br />

rate to be expected on this symbol stream during the<br />

lifetime of the <strong>Service</strong> Agreement. Composed of two<br />

elements (minSymbolRate, maxSymbolRate).<br />

pair of<br />

Unsigned<br />

Integers<br />

millisymbols/<br />

second<br />

acquisitionSequence-<br />

Length<br />

minDelayTime<br />

minimumIdleLength<br />

Table 7-31: FTcModulationProdAgreement Data Set<br />

Name Definition/Description Data Type Units<br />

The length of the acquisition sequence used in Unsigned bits<br />

Telecommand Carrier Modulation Mode (CMM) 2. Integer<br />

The default value is 16.<br />

The minimum value allowed for the delay-time<br />

parameter of the TRANSFER-DATA invocations<br />

carried by the transfer service instance.<br />

The length of the Idle Sequence to be used in Carrier<br />

Modulation Mode (CMM) 4 when PLOP-1 is used.<br />

NOTE – Meaningful only if parameter<br />

plopInEffect is equal to ‘plop-1’. If<br />

plopInEffect = ‘plop-2’, the value<br />

is ‘NULL’.<br />

Unsigned<br />

Integer<br />

Unsigned<br />

Integer in<br />

range<br />

[0..2040] or<br />

‘NULL’<br />

microseconds<br />

bits<br />