13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatus9.7 PREPARING HIGH VOLTAGEELECTRICAL APPARATUS FOR ACCESS9.7.1 Isolati<strong>on</strong> and EarthingHigh <strong>voltage</strong> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus should not beregarded as being safe <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> the issue <str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g>access permit until it has been isolated andearthed.C<strong>on</strong>siderati<strong>on</strong> shall be given to the isolati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g>sources <str<strong>on</strong>g>of</str<strong>on</strong>g> supply from low <strong>voltage</strong> <strong>or</strong> sec<strong>on</strong>darycircuits.Organisati<strong>on</strong>al procedures shall ensure theintegrity <str<strong>on</strong>g>of</str<strong>on</strong>g> the isolati<strong>on</strong> is maintained duringcurrency <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit.Isolati<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> access shall either be visible, <strong>or</strong> anapproved means used to c<strong>on</strong>firm that the <str<strong>on</strong>g>electrical</str<strong>on</strong>g>apparatus is de-energised.Note: Such isolati<strong>on</strong> may not eliminate the effects<str<strong>on</strong>g>of</str<strong>on</strong>g> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> <strong>or</strong> magnetic inducti<strong>on</strong>.Earths shall be applied as described in Clause 8.2.If earthing is not practicable other appropriateprecauti<strong>on</strong>s shall be taken and the auth<strong>or</strong>ised<str<strong>on</strong>g>electrical</str<strong>on</strong>g> operat<strong>or</strong> shall advise the recipient inBlue Book – December 2005 Page 99 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!