13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatus9.7.4 High Voltage Metal-Clad Switchgear andAssociated Electrical Apparatus9.7.4.1 F<strong>or</strong> the purpose <str<strong>on</strong>g>of</str<strong>on</strong>g> issuing an <str<strong>on</strong>g>electrical</str<strong>on</strong>g>access permit, a circuit breaker <strong>or</strong> a <strong>voltage</strong>trans<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>mer may be regarded as isolated and atearth potential when it is racked out, andappropriate precauti<strong>on</strong>s taken to prevent reenergisati<strong>on</strong>.(see also Clause 9.1)9.7.4.2 F<strong>or</strong> <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> <strong>on</strong> busbar circuits, where thephysical separati<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> circuits within a chamber isnot visibly evident, additi<strong>on</strong>al precauti<strong>on</strong>s shall betaken <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> the <str<strong>on</strong>g>safety</str<strong>on</strong>g> <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>ing party.9.7.4.3 The proposed means <str<strong>on</strong>g>of</str<strong>on</strong>g> access withinmetal-clad chambers shall be described to theauth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g> operat<strong>or</strong> by the recipient incharge and both must agree <strong>on</strong> the extent <str<strong>on</strong>g>of</str<strong>on</strong>g>access and that such access is safe.9.7.4.4 When access is required within spoutbushings the c<strong>on</strong>tacts shall be c<strong>on</strong>firmed as deenergisedby an approved test. The circuit shallalso be earthed elsewhere <strong>or</strong> other precauti<strong>on</strong>staken to ensure that the spout c<strong>on</strong>tacts cannotbecome live by inducti<strong>on</strong> <strong>or</strong> other means.Blue Book – December 2005 Page 107 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!