13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatus9.4 OUT OF COMMISSION ELECTRICALAPPARATUS9.4.1 Declaring Electrical Apparatus Out <str<strong>on</strong>g>of</str<strong>on</strong>g>Commissi<strong>on</strong>An out <str<strong>on</strong>g>of</str<strong>on</strong>g> commissi<strong>on</strong> written declarati<strong>on</strong> shallinclude a statement <str<strong>on</strong>g>of</str<strong>on</strong>g> the c<strong>on</strong>diti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g>apparatus including all relevant auxiliaryequipment (eg. c<strong>on</strong>trol circuits, compressed airsupplies, etc)9.4.2 Access to Out Of Commissi<strong>on</strong> ElectricalApparatusElectrical apparatus which is declared ‘out <str<strong>on</strong>g>of</str<strong>on</strong>g>commissi<strong>on</strong>’ may be approached and <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>ed up<strong>on</strong>without the issue <str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit, <strong>or</strong>sancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> testing.Although the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus is not <str<strong>on</strong>g>electrical</str<strong>on</strong>g>lyc<strong>on</strong>nected, due regard shall be given to thepossibility <str<strong>on</strong>g>of</str<strong>on</strong>g> inadvertent energisati<strong>on</strong> fromadjacent <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus, inducti<strong>on</strong>, lightning,static charges, <strong>or</strong> other means.9.5 SUSPENSION OF AN ACCESSAUTHORITY9.5.1 GeneralWhen the operating auth<strong>or</strong>ity and therecipient/tester in charge agree an access auth<strong>or</strong>ityPage 94 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148 Blue Book – December 2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!