13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatusstatements between the auth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g>operat<strong>or</strong> and the recipient in charge beingc<strong>on</strong>firmed by a witness at each end.9.2.5.3 At the time <str<strong>on</strong>g>of</str<strong>on</strong>g> issue the auth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g>operat<strong>or</strong> shall describe and, where practicable,show the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus covered by the<str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit and the precauti<strong>on</strong>s taken,to the recipient in charge and all the initialrecipients.The auth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g> operat<strong>or</strong> shall alsodescribe <strong>or</strong> point out the <strong>near</strong>est points <str<strong>on</strong>g>of</str<strong>on</strong>g> supplyand adjacent live <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus. In the case<str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit issued by teleph<strong>on</strong>e<strong>or</strong> radio the recipient in charge shall assume theseresp<strong>on</strong>sibilities.9.2.5.4 Each <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit shall beissued to a recipient in charge. The recipient incharge shall ensure that all members <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>party who will approach the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatussign <strong>on</strong> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit.9.2.5.5 The issuer and auth<strong>or</strong>ised recipients allhave a resp<strong>on</strong>sibility to ensure that the c<strong>on</strong>diti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g>the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus, covered by the <str<strong>on</strong>g>electrical</str<strong>on</strong>g>access permit, is such that it shall be safe <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> theproposed <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> to be undertaken.Blue Book – December 2005 Page 81 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!