13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatuscan be suspended in acc<strong>or</strong>dance with<strong>or</strong>ganisati<strong>on</strong>al procedures.9.5.2 C<strong>on</strong>diti<strong>on</strong>s <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Suspensi<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> an AccessAuth<strong>or</strong>ity• An access auth<strong>or</strong>ity is not c<strong>on</strong>sideredsuspended until all recipients have signed <str<strong>on</strong>g>of</str<strong>on</strong>g>f.• Recipients sign <str<strong>on</strong>g>of</str<strong>on</strong>g>f and have no access to the<str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus while the accessauth<strong>or</strong>ity is suspended.• The operating auth<strong>or</strong>ity is in<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>med <str<strong>on</strong>g>of</str<strong>on</strong>g> thec<strong>on</strong>diti<strong>on</strong>/status <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus.9.5.3 Procedure <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Suspensi<strong>on</strong> <strong>on</strong> an AccessAuth<strong>or</strong>ityOrganisati<strong>on</strong>al procedures <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> suspensi<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> anaccess auth<strong>or</strong>ity shall ensure that:• The recipient /tester in charge ensures that allrecipients sign <str<strong>on</strong>g>of</str<strong>on</strong>g>f and are in<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>med that theaccess auth<strong>or</strong>ity is suspended and no furtheraccess is permitted;• The operating auth<strong>or</strong>ity is notified <str<strong>on</strong>g>of</str<strong>on</strong>g> thestatus <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus; and• While suspended the access auth<strong>or</strong>ity isunder the c<strong>on</strong>trol <str<strong>on</strong>g>of</str<strong>on</strong>g> the operating auth<strong>or</strong>ity.Blue Book – December 2005 Page 95 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!