Approach To Electrical Apparatus6.4 SAFE APPROACH DISTANCES –UNINSULATED MOBILE PLANT6.4.1 GeneralBecause <str<strong>on</strong>g>of</str<strong>on</strong>g> the physical capabilities <str<strong>on</strong>g>of</str<strong>on</strong>g>, andpotential hazard with mobile plant <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>ing adjacentto live c<strong>on</strong>duct<strong>or</strong>s and/<strong>or</strong> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus,specific c<strong>on</strong>siderati<strong>on</strong> (including earthing) shall begiven to its use during planning <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>. (Refer5.4)6.4.2 Ordinary Pers<strong>on</strong>sAn <strong>or</strong>dinary pers<strong>on</strong> in charge <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> shall,ensure that the mobile plant, its equipment andload is not placed <strong>or</strong> moved within the distancesshown in Table 4.6.4.3 Instructed Pers<strong>on</strong>s <strong>or</strong> Auth<strong>or</strong>ised Pers<strong>on</strong>sAn instructed pers<strong>on</strong> <strong>or</strong> auth<strong>or</strong>ised pers<strong>on</strong> incharge <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> shall ensure that the mobileplant, its gear and load shall not approach livec<strong>on</strong>duct<strong>or</strong>s and/<strong>or</strong> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus within thedistances as shown in Table 4.When <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>ing under glove and barrier procedures,and where the c<strong>on</strong>duct<strong>or</strong>s and load are suitablyinsulated, the load should remain a minimum <str<strong>on</strong>g>of</str<strong>on</strong>g> 380Page 62 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148 Blue Book – December 2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!