13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

Create successful ePaper yourself

Turn your PDF publications into a flip-book with our unique Google optimized e-Paper software.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatus9.2.7 Rejecti<strong>on</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> a RecipientA pers<strong>on</strong> shall recommend the exclusi<strong>on</strong> from an<str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit <str<strong>on</strong>g>of</str<strong>on</strong>g> any other pers<strong>on</strong> who atanytime is c<strong>on</strong>sidered unsafe as a recipient. Suchinstances shall be rep<strong>or</strong>ted promptly to the pers<strong>on</strong>in charge <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>.9.2.8 Absence <str<strong>on</strong>g>of</str<strong>on</strong>g> an Earth <strong>on</strong> ElectricalApparatus Under Electrical Access PermitWherever practicable <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus shall beearthed be<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>e the issue <str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g> accesspermit.Where an earth has not been applied to <str<strong>on</strong>g>electrical</str<strong>on</strong>g>apparatus pri<strong>or</strong> to the issue <str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g> accesspermit the recipient in charge shall arrange <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>discharging and/<strong>or</strong> earthing <str<strong>on</strong>g>of</str<strong>on</strong>g> the <str<strong>on</strong>g>electrical</str<strong>on</strong>g>apparatus be<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>e any recipient touches the <strong>high</strong><strong>voltage</strong> c<strong>on</strong>duct<strong>or</strong>s.9.2.9 Recipient W<strong>or</strong>king Al<strong>on</strong>eAn <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit may be issued to <strong>on</strong>eauth<strong>or</strong>ised recipient, <strong>or</strong> a recipient may <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> al<strong>on</strong>eunder the terms <str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit, <strong>on</strong>lyin acc<strong>or</strong>dance with Organisati<strong>on</strong>al procedures.Page 84 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148 Blue Book – December 2005

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!