13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Access <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> W<strong>or</strong>k <strong>on</strong> <strong>or</strong> Near High Voltage ElectricalApparatusResp<strong>on</strong>sible at the Remote Locati<strong>on</strong>.A Complementary Sancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Testing shall <strong>on</strong>ly beissued after, and relinquished be<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>e, the sancti<strong>on</strong><str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> testing at the nominated main locati<strong>on</strong>. Suchissues and cancellati<strong>on</strong>s shall take place <strong>on</strong>ly withthe approval <str<strong>on</strong>g>of</str<strong>on</strong>g> the tester in charge.9.3.1.5 A sancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> testing and ComplementarySancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Testing shall be issued and cancelled<strong>on</strong>ly by an auth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g> operat<strong>or</strong>.9.3.1.6 The appropriate provisi<strong>on</strong>s <str<strong>on</strong>g>of</str<strong>on</strong>g> Clauses 7, 8,and 9 shall also apply to sancti<strong>on</strong>s <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> testing andComplementary Sancti<strong>on</strong>s <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Testing.9.3.1.7 A sancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> testing <strong>or</strong> a ComplementarySancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Testing may be issued <strong>or</strong> relinquishedby teleph<strong>on</strong>e <strong>or</strong> radio, subject to the statementsbetween the auth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g> operat<strong>or</strong> and thetester-in-charge <strong>or</strong> Tester Resp<strong>on</strong>sible at RemoteLocati<strong>on</strong>, as appropriate, being c<strong>on</strong>firmed by awitness at each end.9.3.1.8 In the case <str<strong>on</strong>g>of</str<strong>on</strong>g> a sancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> testing <strong>or</strong> aComplementary Sancti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> Testing issued byteleph<strong>on</strong>e <strong>or</strong> radio, the Tester-in-Charge <strong>or</strong> theTester Resp<strong>on</strong>sible at Remote Locati<strong>on</strong>, asappropriate, shall assume the resp<strong>on</strong>sibilities <str<strong>on</strong>g>of</str<strong>on</strong>g> theauth<strong>or</strong>ised <str<strong>on</strong>g>electrical</str<strong>on</strong>g> operat<strong>or</strong> in applying theseprovisi<strong>on</strong>s.Blue Book – December 2005 Page 89 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!