13.07.2015 Views

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

code of practice of electrical safety for work on or near high voltage

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

Earthing <str<strong>on</strong>g>of</str<strong>on</strong>g> High Voltage Electrical Apparatus8.6 HIGH VOLTAGE CAPACITORSTo declare <strong>high</strong> <strong>voltage</strong> capacit<strong>or</strong>s safe <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> theissue <str<strong>on</strong>g>of</str<strong>on</strong>g> an <str<strong>on</strong>g>electrical</str<strong>on</strong>g> access permit, the neutral aswell as the actives shall be earthed and, in additi<strong>on</strong>,each individual capacit<strong>or</strong> shall be dischargedbe<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>e it is touched. The same precauti<strong>on</strong>s shall betaken <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g> <strong>on</strong> <str<strong>on</strong>g>electrical</str<strong>on</strong>g> apparatus whichinc<strong>or</strong>p<strong>or</strong>ates <strong>high</strong> <strong>voltage</strong> capacit<strong>or</strong>s (e.g.capacit<strong>or</strong> <strong>voltage</strong> trans<str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g>mers, carrier couplingcapacit<strong>or</strong>s).8.7 OVERHEAD LINES – PRIORITY EARTHINGSYSTEMThe choice <str<strong>on</strong>g>of</str<strong>on</strong>g> c<strong>on</strong>necti<strong>on</strong> <str<strong>on</strong>g>f<strong>or</strong></str<strong>on</strong>g> an earthing deviceshould where practicable be made <strong>on</strong> the basis <str<strong>on</strong>g>of</str<strong>on</strong>g>the following <strong>or</strong>der <str<strong>on</strong>g>of</str<strong>on</strong>g> preference:1. Permanently installed earthing system at the<str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>site, including the neutral c<strong>on</strong>duct<strong>or</strong> <str<strong>on</strong>g>of</str<strong>on</strong>g> aComm<strong>on</strong> Multiple Earthed Neutral (CMEN)System [Not to be c<strong>on</strong>fused with a MultipleEarthed Neutral (MEN) System];2. Permanently installed earthing system asclose as possible to the <str<strong>on</strong>g>w<strong>or</strong>k</str<strong>on</strong>g>site (within 2kilometres);Blue Book – December 2005 Page 75 <str<strong>on</strong>g>of</str<strong>on</strong>g> 148

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!