13.07.2015 Views

Model 7002Switch System Instruction Manual - Advanced Test ...

Model 7002Switch System Instruction Manual - Advanced Test ...

Model 7002Switch System Instruction Manual - Advanced Test ...

SHOW MORE
SHOW LESS

You also want an ePaper? Increase the reach of your titles

YUMPU automatically turns print PDFs into web optimized ePapers that Google loves.

4Front Panel Operation4.1 IntroductionThis section covers all aspects of front panel operation. Paragraphsin this section are organized as follows:4.2 Power-up procedure: Covers information on connectingthe instrument to line power, and the power-up sequence.4.3 Displays: Covers the two displays of the <strong>Model</strong> 7002;the vacuum fluorescent display (VFD) that is used foralphanumeric information and the LED display thatprovides status information for each channel.4.4 Analog backplane: Explains how two or more <strong>Model</strong>701X switching cards may be internally connected togetherthrough the analog backplane of the <strong>Model</strong>7002.4.5 Light pen option: Explains how to use the optionallight pen and summarizes the operations that can beperformed with it.4.6 Display modes: Covers the two display modes thatcan be used for normal operation; the relay status displaymode and the list display mode.4.7 Channel assignments: Explains the channel assignmentformats necessary to program the <strong>Model</strong> 7002.4.8 Channel list and Scan list: Explains how to create achannel list (for open/close operations) and a scan list(for scanning operations).4.9 Closing and opening channels: Explains how toclose and open channels.4.10 Scanning channels: Explains how to scan channels.4.11 Channel patterns: Explains how to create (store)channel patterns, and how to recall them frommemory.4.12 Menu: Covers miscellaneous operations and selectionscontrolled from the MAIN MENU.4.13 Card configuration: Covers the various configurationoperations for the 10 slots (Card 1 through Card 10)using the CARD CONFIG MENU.4.14 Scan configuration: Covers the CONFIGURE SCANmenu, which is used to configure the three layers ofthe scan operation.4.15 Digital I/O port: Covers the input/output port, whichconsists of four output lines and one input line.4.16 External triggering: Covers external triggering usingthe rear panel BNC connectors.4.17 Trigger link: Covers external triggering using the triggerlink.4.2 Power-up procedureThe <strong>Model</strong> 7002 can be operated from line voltages from100-240VAC at line frequencies of 50 or 60Hz.4-1

Hooray! Your file is uploaded and ready to be published.

Saved successfully!

Ooh no, something went wrong!