SQ251 <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> Probe<br />

1.4 Construction and mode of operation<br />

The gas-sampling probe is basically constructed from four units:<br />

• sampling chamber,<br />

• cooling pipe with coolant return pipes,<br />

• gas sampling pipe,<br />

• mounting flange.<br />

Legends: 1. Connecting flange for coolant feed 5. Covering flange<br />

2. Connecting flange for coolant return 6. Cooling pipe<br />

3. Measuring gas output 7. <strong>Sampling</strong> chamber<br />

4. Mounting rail 8. <strong>Sampling</strong> opening<br />

Fig. 2 <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> Probe<br />

The sampling chamber is located at the tip of the probe and has a sampling opening at the side. This arrangement<br />

of the opening prevents the direct entry of the gas / dust mixture. The opening is positioned in a partial gas flow<br />

and allows only relatively dust-free gas into the probe.<br />

The cooling pipe in high temperature-resistant special steel is hermetically enclosed and contains the coolant<br />

return pipe. The oval shape of the cooling pipe ensures a high vertical bending strength. The cooling liquid is<br />

carried to the probe tip via two feed pipes and flows back in the intervening space on the outer pipe. The two feed<br />

pipes are fastened at the probe head with a flange and can therefore be disassembled separately and without<br />

problem. A specially developed, synthetic heat transfer fluid is used as the coolant. This liquid has a very high<br />

boiling point and a high heat absorption capacity. The operating temperatures of over 200 °C obtained with the<br />

fluid are higher than the flue gas condensation point and acid dew point of the process gases. The coolant feed /<br />

return hoses are connected to the probe via ball valves, enabling the probe to be removed without loss of coolant.<br />

The gas-sampling pipe is a pipe arranged centrally in the cooling pipe at a distinct separation. The gas enters<br />

through an opening situated in the sampling chamber. This produces a slightly lower dust content in the gas.<br />

When high levels of contamination occur, this pipe can be easily cleaned. As with the two coolants return pipes,<br />

the gas-sampling pipe is joined to the cooling pipe via flange joints and can therefore be easily disassembled.<br />

The mounting flange provides the mechanical joint between the gas-sampling probe and the furnace inlet<br />

chamber or the precalcination chamber. When an automatic device is used for inserting and withdrawing the<br />

probe, the joint cannot be made using a screw-connected flange.<br />

Copyright ® SIEMENS Page 34 04/04