SQ251 <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> Probe<br />
1.4 Construction and mode of operation<br />
The gas-sampling probe is basically constructed from four units:<br />
• sampling chamber,<br />
• cooling pipe with coolant return pipes,<br />
• gas sampling pipe,<br />
• mounting flange.<br />
Legends: 1. Connecting flange for coolant feed 5. Covering flange<br />
2. Connecting flange for coolant return 6. Cooling pipe<br />
3. Measuring gas output 7. <strong>Sampling</strong> chamber<br />
4. Mounting rail 8. <strong>Sampling</strong> opening<br />
Fig. 2 <strong>FLK</strong> <strong>Gas</strong> <strong>Sampling</strong> Probe<br />
The sampling chamber is located at the tip of the probe and has a sampling opening at the side. This arrangement<br />
of the opening prevents the direct entry of the gas / dust mixture. The opening is positioned in a partial gas flow<br />
and allows only relatively dust-free gas into the probe.<br />
The cooling pipe in high temperature-resistant special steel is hermetically enclosed and contains the coolant<br />
return pipe. The oval shape of the cooling pipe ensures a high vertical bending strength. The cooling liquid is<br />
carried to the probe tip via two feed pipes and flows back in the intervening space on the outer pipe. The two feed<br />
pipes are fastened at the probe head with a flange and can therefore be disassembled separately and without<br />
problem. A specially developed, synthetic heat transfer fluid is used as the coolant. This liquid has a very high<br />
boiling point and a high heat absorption capacity. The operating temperatures of over 200 °C obtained with the<br />
fluid are higher than the flue gas condensation point and acid dew point of the process gases. The coolant feed /<br />
return hoses are connected to the probe via ball valves, enabling the probe to be removed without loss of coolant.<br />
The gas-sampling pipe is a pipe arranged centrally in the cooling pipe at a distinct separation. The gas enters<br />
through an opening situated in the sampling chamber. This produces a slightly lower dust content in the gas.<br />
When high levels of contamination occur, this pipe can be easily cleaned. As with the two coolants return pipes,<br />
the gas-sampling pipe is joined to the cooling pipe via flange joints and can therefore be easily disassembled.<br />
The mounting flange provides the mechanical joint between the gas-sampling probe and the furnace inlet<br />
chamber or the precalcination chamber. When an automatic device is used for inserting and withdrawing the<br />
probe, the joint cannot be made using a screw-connected flange.<br />